Programming Guide | VLT® AutomationDrive FC 360
Option
[61]
[70]
[71]
[72]
[73]
[74]
[83]
13-43 Logic Rule Operator 2
Default value:
[0] Disabled
Setup:
1 setup
Data type:
Uint8
Select the 2nd logical operator to be used on the boolean input calculated in parameter 13-40 Logic Rule Boolean 1, parameter 13-41
Logic Rule Operator 1 and parameter 13-42 Logic Rule Boolean 2 and the boolean input coming from parameter 13-42 Logic Rule
Boolean 2. Parameter 13-42 Logic Rule Boolean 2 signifies the boolean input of parameter 13-44 Logic Rule Boolean 3. Parameter 13-40
Logic Rule Boolean 1 and parameter 13-42 Logic Rule Boolean 2 signify the boolean input calculated in parameter 13-40 Logic Rule
Boolean 1, parameter 13-41 Logic Rule Operator 1 and parameter 13-42 Logic Rule Boolean 2.
Option
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
13-44 Logic Rule Boolean 3
Default value:
[0] False
Setup:
1 setup
Data type:
Uint8
222
| Danfoss A/S © 2024.01
Name
Logic rule 5
SL Time-out 3
SL Time-out 4
SL Time-out 5
SL Time-out 6
SL Time-out 7
Broken Belt
Parameter type:
Conversion index:
Change during operation:
Name
Disabled
AND
OR
AND NOT
OR NOT
NOT AND
NOT OR
NOT AND NOT
NOT OR NOT
Parameter type:
Conversion index:
Change during operation:
Option, Array [6]
–
True
Description
Ignore parameter 13-44 Logic Rule
Boolean 3.
Option, Array [6]
–
True
AU275649936274en-001401 / 130R0507