i-PRO WV-X86531-Z2-PTZ User Manual page 66

Table of Contents

Advertisement

2   Operation
2.3   Viewing images from a PC
Displays the camera image.
The current date and time are displayed according to the set [Time display format] and
[Date/time display format].
→8.1 [Basic] to perform basic settings
The set text is displayed on the screen. The number of lines is two.
When H.265 is displayed, when the bit rate is high, it may be displayed at the refresh interval.
⑯[PTZ-Panel]-[Zoom] Buttons
Adjust the zoom manually.
:Adjust the zoom factor in the [Wide angle] direction.
:Zoom (magnification) 1.0 times.
:Adjust the zoom factor in the [Telescope] direction.
⑰[PTZ-panel]-[Focus]
Adjust the focus manually with the buttons.
[Auto]:Automatically adjust focus.
[Near]:Adjust the focus to the [Near].
[Far]:Adjust the focus to the [Far].
[Displays the auto focus frame]:When you draw a frame with the image [On], adjust the focus
(focus) to match the frame.
[Note:]
・Users with low access levels may temporarily change the display but do not affect
the operation of the camera.
・When the shooting scene changes significantly depending on the PC, tiring (a
phenomenon in which a part of the screen is misaligned) may occur due to
constraints in the OS drawing process.
・When the data encryption function is enabled, the image cannot be viewed on the
live screen. Use the corresponding equipment.
・When a high zoom factor image is displayed, the clicked position may not be the
center of the image.
・As the tilt angle approaches 90 degrees, the difference between the specified
position and the actual direction of movement will become larger, and the
specified image angle may not be achieved.
・If the mouse is dragged to move to an angle that exceeds the rotational range of
the camera, the camera moves to the position where it can be operated, and then
the zoom factor is automatically adjusted.