12   [Alarm] to set the alarm
12.10   [Notification] to set alarm notification
Number of characters that can be entered:0 to 63 characters
Characters that cannot be entered:Double-byte and single-byte symbols " & : ; ¥
[Password]
Enter the password to access the HTTP server.
Number of characters that can be entered:0 to 63 characters
Characters that cannot be entered:Double-byte and single-byte symbols " &
[Notification data]
Set the notification content to be added after the HTTP server set to [Address 1] ~ [Address 5].
Input Characters:Half mark alphanumeric characters and marks
Example:
If [/cgi-bin/comalarms.cgi?CMD=01] is set as the notification destination and [/cgi-bin/
comalarms.cgi?CMD=01] is set to the notification destination, the HTTP alarm notification with
http://192.168.0.100/cg i-bin/commalm.cgi?CMD=01 is executed.
[PTZ linkage operation]
This is the setting to perform the operation in cooperation with the PTZ camera. The HTTPS URL
of the PTZ camera is automatically displayed.
[Alarm] field
When checked, the PTZ camera works in conjunction with the camera.
[User name]
The Multi-directional camera administrator user name is automatically displayed.
[Note:]
・Basic or Digest authentication is performed by an HTTP server authentication
request.
[Note:]
・If the HTTP alarm function is enabled, the authentication information (user name,
password) of the HTTP server may be leaked on the network when the alarm is
notified to the HTTP server.
・The number of characters to be notified (including [http://]) and [Notification
data] is limited to 256 characters.
・Be sure to enter the [Notification data] from the slash (/).
・If an HTTP alarm notification fails, it is listed in the system log.
・If [Notification data] is blank and [Set] is pressed, [/cgi-bin/comarm.cgi?
CMD=01] is also set.