i-PRO WV-X86531-Z2-PTZ User Manual page 184

Table of Contents

Advertisement

7   [Easy Setup] to use easy setting
7.3   [Event action] for setting events
[Terminal 1]
Set the operation of terminal 1.
・[Off]:Terminal function is not used.
・[Alarm input(TRM1)]:Terminal alarm input is received.
  ・[Close]:When the terminal status changes to [On], an alarm is detected.
・[Open]:When the terminal status changes to [Off], an alarm is detected.
・[Close(Continue)]:When the terminal status changes to [On], an alarm is detected. When the
terminal status is [On], the alarm is detected periodically at intervals of no alarm detection
time.
・[Open(Continue)]:When the terminal status changes to [Off], an alarm is detected. When the
terminal status is [Off], the alarm is detected periodically at intervals of no alarm detection
time.
・[Black & white input]:Receives black-and-white selector input. (When the input is [On], the
input is switched to black and white)
・[Auto time adjustment]:Time setting by terminal input is accepted. When the signal is input, set
to 00 minutes 00 seconds if the time difference from the normal time (00 minutes per hour) is 29
minutes or less. In the case of returning the time less than 5 seconds during SD recording, the
time is not changed. Selecting Auto Time Adjustment displays the pull-down menu for short
circuit and release selection.
  ・[Close]:When the terminal status changes to [Close], the automatic time adjustment is
performed.
・[Open]:When the terminal status changes to [Open], the automatic time adjustment is
performed.
[Terminal 2]
Set the operation of terminal 2.
・[Off]:Terminal function is not used.
・[Alarm input (TRM2)]:The alarm input is received.
・[Short circuit]:When the terminal status changes to [On], an alarm is detected.
・[Open]:When the terminal status changes to [Off], an alarm is detected.
・[Short circuit (Continued)]:When the terminal status changes to [On], an alarm is detected.
When the terminal status is [On], the alarm is detected periodically at intervals of no alarm
detection time.
・[Open (continued)]:When the terminal status changes to [Off], an alarm is detected. When the
terminal status is [Off], the alarm is detected periodically at intervals of no alarm detection time.
・[Alarm Output]:Alarm outputs according to the setting in [Output terminal].
→12.2 [Alarm] for setting the output terminal
177

Advertisement

Table of Contents
loading

Table of Contents