Application Guide | iC2-Micro Frequency Converters
Bit 13=0: There are no voltage warnings.
Bit 13=1: The DC voltage in the drive's DC link is too low or too high.
Bit 14, Torque OK/Limit Exceeded
Bit 14=0: The motor current is lower than the current limit selected in P 2.7.1 Output Current Limit %.
Bit 14=1: The current limit in P 2.7.1 Output Current Limit % is exceeded.
Bit 15, Timer OK/Limit Exceeded
Bit 15=0: The timers for motor thermal protection and thermal protection are not exceeded 100%.
Bit 15=1: 1 of the timers exceeds 100%.

Bus Speed Reference Value

6.1.8.5
Speed reference value is transmitted to the drive in a relative value in %. The value is transmitted in the form of a 16-bit word. The integer
value 16384 (4000 hex) corresponds to 100%. Negative figures are formatted using 2's complement. The actual output frequency (MAV)
is scaled in the same way as the bus reference.
Master-follower
CTW
Follower-follower
STW
Figure 67: Actual Output Frequency (MAV)
The reference and MAV are scaled as follows:
(C000hex)
P 5.5.3.1 Reference Range
(1) -max- +max
P 5.5.3.3 Reference Maximum
Max reference
P 5.5.3.1 Reference Range
(0) min-max
Figure 68: Reference and MAV
102
| Danfoss A/S © 2024.03
16 bit
Speed reference
Actual output frequency
-100%
Reverse
0%
(0hex)
Forward
0
0%
(0hex)
Forward
P 5.5.3.4 Reference Minimum
Min reference
100%
(4000hex)
P 5.5.3.3 Reference Maximum
Max reference
100%
(4000hex)
P 5.5.3.3 Reference Maximum
Max reference
AB413939445838en-000301 / 130R1254