Application Guide | iC2-Micro Frequency Converters
Table 16: Process Control Mode Default Settings (continued)
Category
AI1 - T33
AI2 - T34
AO1 - T42
Relay
PID
Jog
External reference

Configuring Multi-Speed Control Mode

5.5.4
Multi-speed control mode allows to use 2 digital inputs for 4 different speeds. By using 1 more digital input, 8 speeds are possible.
Danfoss A/S © 2024.03
Parameter index
Parameter name
9.5.2.1
T33 mode
9.5.2.2
T33 High Voltage
9.5.2.3
T33 Low Voltage
T33 High Ref./Feedb.
9.5.2.6
Value
9.5.2.7
T33 Low Ref./Feedb.
Value
9.5.3.1
T34 mode
9.5.3.4
T34 High Current
9.5.3.5
T34 Low Current
9.5.3.6
T34 High Ref./Feedb.
Value
9.5.3.7
T34 Low Ref./Feedb.
Value
9.5.1.1
T31 Mode
9.5.1.2
T31 Analog Output
9.4.3.1
Function Relay
5.12.4.1
Feedback 1 Resource
5.12.5.7
PID Normal / Inverse
Control
5.9.2
Jog Reference
5.9.1
Jog Ramp Time
5.5.3.5
Reference Function
5.5.3.7
Reference 1 Source
5.5.3.8
Reference 2 Source
5.5.3.9
Reference 3 Source
Default setting
Parameter number
[1] Voltage Mode
619
10V
611
0.07 V
610
50
615
0
614
[0] Current Mode
629
20.00 mA
623
4.00 mA
622
50. If [1] North Amer-
625
ica is selected for
P 1.2.1 Regional
Settings, the default
value is 60.
0
624
[0] 0-20mA
690
[100] Output Fre-
691
quency
[9] Fault
540
[2] Analog Input 34
720
[0] Normal
730
5.0
311
3 s
380
[0] Sum
304
[1] Analog Input 33
315
[0] Function
316
[0] Function
317
AB413939445838en-000301 / 130R1254 |
59