Dc-Link Control (Menu Index 2.5) - Danfoss iC2 Application Manual

Micro frequency converters
Table of Contents

Advertisement

Application Guide | iC2-Micro Frequency Converters
P 2.4.5 Over Modulation
Use the parameter to enable or disable overmodulation of the output voltage. Select [1] On to obtain extra DC-link voltage and torque
on the motor shaft. Select [0] Off to avoid torque ripple on the motor shaft.
Default value:
1 [On]
Parameter
1403
number:
Data type:
enum
Following are the selections for the parameter:
Selection number
Selection name
0
Off
1
On

DC-Link Control (Menu Index 2.5)

7.3.4
P 2.5.1 Damping Gain Factor
Damping factor for DC link voltage compensation. See P 2.5.2 DC-Link Voltage Compensation.
Default value:
Size Related
Parameter
1408
number:
Data type:
uint8
P 2.5.2 DC-Link Voltage Compensation
Enable DC-link compensation to reduce ripple in the DC-link voltage (recommended for most applications).
Default value:
Size Related
Parameter
1451
number:
Data type:
enum
Danfoss A/S © 2024.03
Parameter type:
Unit:
Access type:
Selection description
To avoid torque ripple on the motor shaft, select [0] Off for no
overmodulation of the output voltage. This feature may be useful
for applications such as grinding machines.
Select [1] On to enable the overmodulation function for the
output voltage. Select this setting when it is required that the
output voltage is >95% of the input voltage (typical when
running oversynchronously). The output voltage is increased
according to the degree of overmodulation.
  NOTICE
Overmodulation leads to increased torque ripple as
harmonics are increased.
Parameter type:
Unit:
Access type:
Parameter type:
Unit:
Access type:
AB413939445838en-000301 / 130R1254 |
Selection
Read/Write
Range (0–100)
%
Read/Write
Selection
Read/Write
117