Selection number
Selection name
0
Normal
1
Inverse
P 4.4.1.5 Motor Control Bandwidth
Select type of motor control bandwidth.
Default value:
1 [Medium]
Parameter
108
number:
Data type:
enum
The following are the selections for the parameter.
Selection number
Selection name
0
High
1
Medium
2
Low
3
Adaptive 1
4
Adaptive 2

AC-Brake (Menu Index 4.4.2)

7.5.3.2
P 4.4.2.1 Enable AC Brake
Select the method for dissipation of excess brake energy.
Default value:
0 [Disable]
Parameter
210
number:
Data type:
enum
Selection number
0
1
P 4.4.2.2 AC Brake, Max current
130
| Danfoss A/S © 2024.03
Selection description
The motor shaft turns in clockwise direction when frequency
converter is connected U⇒U; V⇒V; and W⇒W to motor.
The motor shaft turns in counterclockwise direction when
frequency converter is connected U⇒U; V⇒V; and W⇒W to
motor.
Parameter type:
Unit:
Access type:
Selection description
For high dynamic response.
Optimized for smooth steady state operation.
Optimized for smooth steady state operation with lowest
dynamic response.
Optimized for smooth steady state operation, with extra active
damping.
Focuses on low-inductance PM motors. This option is an
alternative to [3] Adaptive 1.