Async. Induction Motor (Menu Index 4.2.3) - Danfoss iC2 Application Manual

Micro frequency converters
Table of Contents

Advertisement

Application Guide | iC2-Micro Frequency Converters
Default value:
Size Related
Parameter
125
number:
Data type:
uint16

Async. Induction Motor (Menu Index 4.2.3)

7.5.2.3
P 4.2.3.1 Stator Resistance Rs
Set the stator resistance value. Enter the value from a motor datasheet or perform an AMA on a cold motor.
Default value:
Size Related
Parameter
130
number:
Data type:
uint32
P 4.2.3.2 Rotor Resistance Rr
Enter the rotor resistance value. Obtain the value from a motor datasheet or by performing an AMA on a cold motor. The default setting
is calculated by the drive from motor nameplate data.
Default value:
Size Related
Parameter
131
number:
Data type:
uint32
P 4.2.3.4 Stator Leakage Reactance X1
Set the stator leakage reactance value. Enter the value from a motor datasheet or perform an AMA on a cold motor. The default setting is
calculated by the drive from motor nameplate data.
Default value:
Size Related
Parameter
133
number:
Data type:
uint32
P 4.2.3.6 Main Reactance Xh
Set the main reactance value. Enter the value from a motor datasheet or perform an AMA on a cold motor. The default setting is
calculated by the drive from motor nameplate data.
Default value:
Size Related
Parameter
135
number:
Data type:
uint32
P 4.2.3.7 Motor Cont. Rated Torque
126
| Danfoss A/S © 2024.03
Parameter type:
Unit:
Access type:
Parameter type:
Unit:
Access type:
Parameter type:
Unit:
Access type:
Parameter type:
Unit:
Access type:
Parameter type:
Unit:
Access type:
Range (Size Related)
RPM
Read/Write
Range (Size Related)
Ω
Read/Write
Range (Size Related)
Ω
Read/Write
Range (Size Related)
Ω
Read/Write
Range (Size Related)
Ω
Read/Write
AB413939445838en-000301 / 130R1254