Danfoss iC2 Application Manual page 122

Micro frequency converters
Table of Contents

Advertisement

Application Guide | iC2-Micro Frequency Converters
P 4.1.6 Frequency
View the actual motor frequency value.
Default value:
0.0
Parameter
1613
number:
Data type:
uint32
P 4.1.7 Frequency %
View the actual motor frequency as a percentage of P 5.8.2 Motor Speed High Limit.
Default value:
0.0
Parameter
1615
number:
Data type:
uint16
P 4.1.8 Motor Shaft Speed
View the actual motor RPM. In open loop or closed-loop process control the motor RPM is estimated. In speed closed-loop modes the
motor RPM is measured.
Default value:
0
Parameter
1617
number:
Data type:
int32
P 4.1.10 Motor Torque
View the torque value with sign, applied to the motor shaft. Some motors supply more than 160% torque. As a result, the minimum value
and the maximum value depend on the maximum motor current and the motor used.
Default value:
0.0
Parameter
1616
number:
Data type:
int32
P 4.1.11 Motor Torque %
View the torque in percent of nominal torque, with sign, applied to the motor shaft.
Default value:
0
Parameter
1622
number:
Data type:
int16
122
| Danfoss A/S © 2024.03
Parameter type:
Unit:
Access type:
Parameter type:
Unit:
Access type:
Parameter type:
Unit:
Access type:
Parameter type:
Unit:
Access type:
Parameter type:
Unit:
Access type:
Range (0.0–6553.5)
Hz
Read
Range (0–6553.5)
%
Read
Range (-30000.0–30000.0)
RPM
Read
Range (-30000.0–30000.0)
Nm
Read
Range (-200–200)
%
Read
AB413939445838en-000301 / 130R1254