Application Guide | iC2-Micro Frequency Converters
General Reference
parameters:
Reference Range: Min - Max
Minimum Reference: 0 Hz (0,0%)
Maximum Reference: 20 Hz (100,0%)
AI 33
Low reference 0 Hz
High reference 20 Hz
Low voltage 1 V
Ext. Reference
High voltage 10 V
Absolute
0 Hz 1 V
Ext. source 1
20 Hz 10V
Range:
0.0% (0 Hz)
100.0% (20 Hz)
20
DI 14
Digital input
Low No reversing
High Reversing
Figure 49: Clamping of Reference Input with Limits inside Minimum to Maximum
Case 2: Positive reference with dead band, digital input to trigger reverse, part II
Figure 50
shows how reference input with limits outside -maximum to +maximum limits clamps to the input low and high limits before
adding to external reference, and how the external reference is clamped to -maximum to +maximum by the reference algorithm.
Danfoss A/S © 2024.03
Limited to: -200%- +200%
(-40 Hz- +40 Hz)
Ext. reference
+
Range:
0.0% (0 Hz)
100.0% (20 Hz)
Reference is scaled
according to min
max reference giving a
speed.!!!
Hz
V
10
1
Limits Speed Setpoint
according to min max speed.!!!
General Motor
parameters:
Motor speed direction:Both directions
Motor speed Low limit: 0 Hz
Motor speed high limit: 8 Hz
Reference
Limited to:
algorithm
0%- +100%
(0 Hz- +20 Hz)
Reference
Range:
0.0% (0 Hz)
100.0% (20 Hz)
Hz
Scale to
20
speed
1
Speed
setpoint
Range:
-20
-20 Hz
+20 Hz
Motor PID
Range:
Motor
-8 Hz
control
+8 Hz
AB413939445838en-000301 / 130R1254 |
Dead band
V
10
Motor
71