Application Guide | iC2-Micro Frequency Converters
FC Port Diagnostics (Menu Index 10.2)
7.10.2
P 10.2.1 Bus Message Count
This parameter shows the number of valid telegrams detected on the bus.
Default value:
0
Parameter
880
number:
Data type:
uint32
P 10.2.1 Bus Error Count
This parameter shows the number of telegrams with faults (for example, CRC fault), detected on the bus.
Default value:
0
Parameter
881
number:
Data type:
uint32
P 10.2.3 Slave Messaged Rcvd
This parameter shows the number of valid telegrams addressed to the slave, sent by the frequency converter.
Default value:
0
Parameter
882
number:
Data type:
uint32
P 10.2.4 Slave Error Count
This parameter shows the number of valid telegrams addressed to the slave, sent by the frequency converter.
Default value:
0
Parameter
883
number:
Data type:
uint32
P 10.2.5 Slave Messages Sent
This parameter shows the number of messages sent from the slave.
Default value:
0
Parameter
884
number:
Data type:
uint32
Danfoss A/S © 2024.03
Parameter type:
Unit:
Access type:
Parameter type:
Unit:
Access type:
Parameter type:
Unit:
Access type:
Parameter type:
Unit:
Access type:
Parameter type:
Unit:
Access type:
AB413939445838en-000301 / 130R1254 |
Range (0–4294967295)
Read
Range (0–4294967295)
Read
Range (0–4294967295)
Read
Range (0–4294967295)
Read
Range (0–4294967295)
Read
259