Sign In
Upload
Manuals
Brands
Danfoss Manuals
Media Converter
VLT HVAC Basic Drive FC 101
Danfoss VLT HVAC Basic Drive FC 101 Manuals
Manuals and User Guides for Danfoss VLT HVAC Basic Drive FC 101. We have
14
Danfoss VLT HVAC Basic Drive FC 101 manuals available for free PDF download: Design Manual, Programming Manual, Operating Manual, Quick Manual
Danfoss VLT HVAC Basic Drive FC 101 Design Manual (124 pages)
Brand:
Danfoss
| Category:
DC Drives
| Size: 5 MB
Table of Contents
Table of Contents
3
1 Introduction
8
Purpose of the Design Guide
8
Document and Software Version
8
Safety Symbols
8
Abbreviations
8
Additional Resources
9
Definitions
9
Power Factor
11
Regulatory Compliance
11
CE Mark
11
UL Compliance
12
RCM Mark Compliance
12
2 Safety
13
Qualified Personnel
13
Safety Precautions
13
3 Product Overview
15
Advantages
15
Why Use a Frequency Converter for Controlling Fans and Pumps
15
The Clear Advantage - Energy Savings
15
Example of Energy Savings
15
Comparison of Energy Savings
16
Example with Varying Flow over 1 Year
17
Better Control
17
Star/Delta Starter or Soft Starter Not Required
18
Using a Frequency Converter Saves Money
18
Without a Frequency Converter
19
With a Frequency Converter
20
Application Examples
21
Variable Air Volume
21
The VLT Solution
21
Constant Air Volume
22
The VLT Solution
22
Cooling Tower Fan
23
The VLT Solution
23
Condenser Pumps
24
The VLT Solution
24
Primary Pumps
25
The VLT Solution
25
Secondary Pumps
27
The VLT Solution
27
Control Structures
28
Control Structure Open Loop
28
PM/EC+ Motor Control
28
Local (Hand On) and Remote (Auto On) Control
28
Control Structure Closed Loop
29
Feedback Conversion
30
Reference Handling
31
Tuning the Drive Closed-Loop Controller
32
Manual PI Adjustment
32
Ambient Running Conditions
32
General Aspects of EMC
38
Overview of EMC Emissions
38
Emission Requirements
39
EMC Emission Test Results
41
Overview of Harmonics Emission
42
Harmonics Emission Requirements
42
Harmonics Test Results (Emission)
42
Immunity Requirements
44
Galvanic Isolation (PELV)
44
Earth Leakage Current
45
Extreme Running Conditions
45
Motor Thermal Protection (ETR)
46
Thermistor Inputs
46
4 Selection and Ordering
48
Type Code
48
Options and Accessories
49
Local Control Panel (LCP)
49
Mounting of LCP in Panel Front
49
IP21/NEMA Type 1 Enclosure Kit
50
Decoupling Plate
51
Ordering Numbers
52
Options and Accessories
52
Harmonic Filters
53
External RFI Filter
54
5 Installation
55
Electrical Installation
55
Electrical Installation in General
56
Mains and Motor Connection
57
EMC-Compliant Electrical Installation
62
Control Terminals
64
6 Programming
65
Introduction
65
Local Control Panel (LCP)
65
Menus
66
Status Menu
66
Quick Menu
66
Main Menu
80
Quick Transfer of Parameter Settings between Multiple Frequency Converters
80
Readout and Programming of Indexed Parameters
81
Initialization to Default Settings
81
7 RS485 Installation and Set-Up
82
Rs485
82
Overview
82
Network Connection
82
Frequency Converter Hardware Set-Up
83
Parameter Settings for Modbus Communication
83
EMC Precautions
84
FC Protocol
84
Overview
84
FC with Modbus RTU
84
Parameter Settings to Enable the Protocol
85
FC Protocol Message Framing Structure
85
Content of a Character (Byte)
85
Telegram Structure
85
Telegram Length (LGE)
85
Frequency Converter Address (ADR)
85
Data Control Byte (BCC)
85
The Data Field
85
The PKE Field
86
Parameter Number (PNU)
86
Index (IND)
86
Parameter Value (PWE)
87
Data Types Supported by the Frequency Converter
87
Conversion
87
Process Words (PCD)
87
Examples
87
Writing a Parameter Value
87
Reading a Parameter Value
88
Modbus RTU Overview
88
Introduction
88
Overview
88
Frequency Converter with Modbus RTU
89
Network Configuration
89
Modbus RTU Message Framing Structure
89
Introduction
89
Modbus RTU Telegram Structure
89
Start/Stop Field
90
Address Field
90
Function Field
90
Data Field
90
CRC Check Field
90
Coil Register Addressing
90
Access Via PCD Write/Read
92
How to Control the Frequency Converter
93
Function Codes Supported by Modbus RTU
93
Modbus Exception Codes
93
How to Access Parameters
94
Parameter Handling
94
Storage of Data
94
IND (Index)
94
Text Blocks
94
Conversion Factor
94
Parameter Values
94
Examples
94
Read Coil Status (01 Hex)
94
Force/Write Single Coil (05 Hex)
95
Force/Write Multiple Coils (0F Hex)
96
Read Holding Registers (03 Hex)
96
Preset Single Register (06 Hex)
96
Preset Multiple Registers (10 Hex)
97
Read/Write Multiple Registers (17 Hex)
97
Danfoss FC Control Profile
98
Control Word According to FC Profile (8-10 Protocol = FC Profile)
98
Status Word According to FC Profile (STW)
99
Bus Speed Reference Value
100
Advertisement
Danfoss VLT HVAC Basic Drive FC 101 Design Manual (132 pages)
Brand:
Danfoss
| Category:
DC Drives
| Size: 11 MB
Table of Contents
Table of Contents
3
1 Introduction
7
Purpose of the Manual
7
Document and Software Version
7
Safety Symbols
7
Abbreviations
7
Additional Resources
8
Definitions
8
Power Factor
10
2 Product Overview
11
Safety
11
CE Labeling
12
Air Humidity
13
Aggressive Environments
14
Vibration and Shock
14
Advantages
14
Control Structures
28
Control Principle
28
Control Structure Open-Loop
28
PM/EC+ Motor Control
28
Local (Hand On) and Remote (Auto On) Control
29
Control Structure Closed-Loop
30
Feedback Conversion
30
Reference Handling
31
Closed-Loop Set-Up Wizard
33
Tuning the Drive Closed-Loop Controller
36
Manual PI Adjustment
36
General Aspects of EMC
37
Emission Requirements
38
Galvanic Isolation (PELV)
43
Ground Leakage Current
44
Extreme Running Conditions
44
3 Selection
47
Options and Accessories
47
Local Control Panel (LCP)
47
Mounting of LCP in Panel Front
47
IP21/TYPE 1 Enclosure Kit
48
Decoupling Plate
50
4 How to Order
51
Configuration
51
Ordering Numbers
53
5 How to Install
56
Mechanical Dimensions
56
Adjustable Frequency Drive Dimensions
56
Shipping Dimensions
59
Electrical Data
60
Electrical Installation in General
61
Connecting to Line Power and Motor
62
Fuses and Circuit Breakers
69
Control Terminals
74
6 How to Program
75
Programming with MCT 10 Set-Up Software
75
Local Control Panel (LCP)
75
Menus
76
Status Menu
76
Quick Menu
76
Start-Up Wizard for Open-Loop Applications
76
Main Menu
86
Quick Transfer of Parameter Settings between Multiple Adjustable Frequency Drives
86
Readout and Programming of Indexed Parameters
86
Initialize the Adjustable Frequency Drive to Default Settings in Two Ways
87
7 Installation and Set-Up
88
Rs-485
88
Overview
88
Network Connection
88
Adjustable Frequency Drive Hardware Set-Up
89
EMC Precautions
90
Adjustable Frequency Protocol Overview
90
Network Configuration
90
FC Protocol Message Framing Structure
91
Content of a Character (Byte)
91
Message Structure
91
Message Length (LGE)
91
Adjustable Frequency Drive Address (ADR)
91
Data Control Byte (BCC)
91
The Data Field
92
The PKE Field
93
Parameter Number (PNU)
93
Index (IND)
93
Parameter Value (PWE)
94
Data Types Supported by the Adjustable Frequency Drive
94
Conversion
94
Process Words (PCD)
94
Examples
94
Modbus RTU Overview
95
Assumptions
95
What the User Should Already Know
95
Adjustable Frequency Drive with Modbus RTU
96
Network Configuration
96
Modbus RTU Message Framing Structure
96
Modbus RTU Message Structure
97
Start/Stop Field
97
Address Field
97
Function Field
97
Data Field
97
CRC Check Field
98
Coil Register Addressing
98
How to Control the Adjustable Frequency Drive
100
Function Codes Supported by Modbus RTU
100
Modbus Exception Codes
100
How to Access Parameters
101
Parameter Handling
101
Storage of Data
101
Ind
101
Text Blocks
101
Conversion Factor
101
Parameter Values
101
Examples
101
Read Coil Status (01 HEX)
101
Force/Write Single Coil (05 HEX)
102
Force/Write Multiple Coils (0F HEX)
103
Read Holding Registers (03 HEX)
103
Preset Single Register (06 HEX)
104
Preset Multiple Registers (10 HEX)
104
Danfoss FC Control Profile
105
Control Word According to FC Profile (8-10 Protocol = FC Profile)
105
Status Word According to FC Profile (STW) (8-30 Protocol = FC Profile)
106
Bus Speed Reference Value
107
Danfoss VLT HVAC Basic Drive FC 101 Design Manual (124 pages)
VLT HVAC Basic Drive FC 101 Frequency converter
Brand:
Danfoss
| Category:
Media Converter
| Size: 6 MB
Table of Contents
Table of Contents
3
1 Introduction
7
Purpose of the Manual
7
Document and Software Version
7
Safety Symbols
7
Abbreviations
7
Additional Resources
8
Definitions
8
Power Factor
10
2 Product Overview
11
Safety
11
CE Labeling
12
Air Humidity
13
Aggressive Environments
13
Vibration and Shock
14
Advantages
14
Application Examples
19
Control Structures
27
Control Principle
27
Control Structure Open Loop
27
PM/EC+ Motor Control
27
Local (Hand On) and Remote (Auto On) Control
28
Control Structure Closed Loop
28
Feedback Conversion
28
Reference Handling
29
Closed Loop Set-Up Wizard
30
Tuning the Drive Closed Loop Controller
33
Manual PI Adjustment
33
General Aspects of EMC
34
Emission Requirements
35
Galvanic Isolation (PELV)
39
Earth Leakage Current
40
Extreme Running Conditions
40
3 Selection
43
Options and Accessories
43
Local Control Panel (LCP)
43
Mounting of LCP in Panel Front
43
IP21/TYPE 1 Enclosure Kit
44
Decoupling Plate
45
4 How to Order
46
Configuration
46
Ordering Numbers
47
5 How to Install
51
Mechanical Dimensions
51
Frequency Converter Dimensions
51
Shipping Dimensions
53
Side-By-Side Installation
54
Electrical Data
55
Electrical Installation in General
56
Connecting to Mains and Motor
57
Fuses and Circuit Breakers
64
Control Terminals
69
6 How to Programme
70
Programming with MCT 10 Set-Up Software
70
Local Control Panel (LCP)
70
Menus
71
Status Menu
71
Quick Menu
71
Start-Up Wizard for Open Loop Applications
71
Main Menu
80
Quick Transfer of Parameter Settings between Multiple Frequency Converters
80
Read-Out and Programming of Indexed Parameters
80
Initialise the Frequency Converter to Default Settings in Two Ways
80
7 Installation and Set-Up
82
Rs-485
82
Overview
82
Network Connection
82
Frequency Converter Hardware Set-Up
82
Frequency Converter Parameter Settings for Modbus Communication
83
EMC Precautions
83
FC Protocol Overview
83
Network Configuration
84
FC Protocol Message Framing Structure
84
Content of a Character (Byte)
84
Telegram Structure
84
Telegram Length (LGE)
84
Frequency Converter Address (ADR)
84
Data Control Byte (BCC)
84
The Data Field
85
The PKE Field
86
Parameter Number (PNU)
86
Index (IND)
86
Parameter Value (PWE)
86
Data Types Supported by the Frequency Converter
87
Conversion
87
Process Words (PCD)
87
Examples
87
Modbus RTU Overview
88
Assumptions
88
What the User Should Already Know
88
Frequency Converter with Modbus RTU
89
Network Configuration
89
Modbus RTU Message Framing Structure
89
Modbus RTU Message Structure
89
Start/Stop Field
90
Address Field
90
Function Field
90
Data Field
90
CRC Check Field
90
Coil Register Addressing
90
How to Control the Frequency Converter
92
Function Codes Supported by Modbus RTU
92
Modbus Exception Codes
93
How to Access Parameters
93
Parameter Handling
93
Storage of Data
93
Ind
93
Text Blocks
93
Conversion Factor
93
Parameter Values
93
Examples
94
Read Coil Status (01 HEX)
94
Force/Write Single Coil (05 HEX)
94
Force/Write Multiple Coils (0F HEX)
95
Read Holding Registers (03 HEX)
95
Preset Single Register (06 HEX)
95
Preset Multiple Registers (10 HEX)
96
Danfoss FC Control Profile
96
Control Word According to FC Profile (8-10 Protocol = FC Profile)
96
Status Word According to FC Profile (STW) (8-30 Protocol = FC Profile)
98
Bus Speed Reference Value
99
Advertisement
Danfoss VLT HVAC Basic Drive FC 101 Design Manual (117 pages)
Brand:
Danfoss
| Category:
DC Drives
| Size: 25 MB
Table of Contents
Table of Contents
2
1 How to Read this Design Guide
5
Legal Information
5
Available Literature for VLT ® HVAC Basic Drive
5
Symbols
6
Abbreviations
6
Definitions
7
Power Factor
9
2 Introduction to VLT
10
Safety
10
CE Labeling
11
Air Humidity
12
Aggressive Environments
12
Vibration and Shock
13
Advantages
13
Control Structures
25
Local (Hand On) and Remote (Auto On) Control
25
General Aspects of EMC
32
Galvanic Isolation (PELV)
37
Earth Leakage Current
38
Extreme Running Conditions
38
3 VLT ® HVAC Basic Drive Selection
41
Options and Accessories
41
Local Control Panel (LCP)
41
Mounting of LCP in Panel Front
41
IP21/TYPE 1 Enclosure Kit
42
Decoupling Plate
43
4 How to Order
44
5 How to Install
49
Dimensions
49
Shipping Dimensions
51
Side-By-Side Installation
52
Electrical Data
53
Electrical Overview
53
Electrical Installation in General
54
Connecting to Mains and Motor
55
Fuses
61
EMC-Correct Electrical Installation
63
Control Terminals
65
6 How to Programme
66
Programming with MCT 10 Setup Software
66
Local Control Panel (LCP)
66
Menus
67
Status
67
Quick Menu
67
Start-Up Wizard for Open Loop Applications
67
Main Menu
76
Quick Transfer of Parameter Settings between Multiple Frequency Converters
76
Read-Out and Programming of Indexed Parameters
76
Initialise the Frequency Converter to Default Settings in Two Ways
77
7 Installation and Set-Up
78
Overview
78
FC Protocol Overview
79
Network Configuration
80
FC Protocol Message Framing Structure
80
Content of a Character (Byte)
80
Telegram Structure
80
Telegram Length (LGE)
80
The Data Field
80
Process Words (PCD)
83
Examples
83
Modbus RTU Overview
83
Assumptions
83
What the User Should Already Know
84
Modbus RTU Overview
84
Frequency Converter with Modbus RTU
84
Network Configuration
84
Modbus RTU Message Framing Structure
84
Modbus RTU Message Structure
85
Start/Stop Field
85
Address Field
85
Function Field
85
Data Field
85
CRC Check Field
86
How to Control the Frequency Converter
87
Function Codes Supported by Modbus RTU
88
Modbus Exception Codes
88
How to Access Parameters
88
Parameter Handling
88
Storage of Data
88
Ind
88
Text Blocks
88
Conversion Factor
89
Parameter Values
89
Examples
89
Force/Write Single Coil (05 HEX)
89
Force/Write Multiple Coils (0F HEX)
90
Preset Single Register (06 HEX)
91
Danfoss FC Control Profile
92
Control Word According to FC Profile (8-10 Protocol = FC Profile)
92
Danfoss VLT HVAC Basic Drive FC 101 Programming Manual (124 pages)
Brand:
Danfoss
| Category:
Media Converter
| Size: 3 MB
Table of Contents
Table of Contents
3
1 Introduction
5
Purpose of the Manual
5
Document and Software Version
5
Safety Symbols
5
Safety Precautions
6
Additional Resources
7
Definitions
7
Electrical Overview
10
2 Programming
11
Introduction
11
Local Control Panel (LCP)
11
Menus
12
Status Menu
12
Quick Menu
12
Main Menu
26
Quick Transfer of Parameter Settings between Multiple Frequency Converters
26
Readout and Programming of Indexed Parameters
27
Initialization to Default Settings
27
3 Parameters
28
Main Menu - Operation and Display - Group
28
Main Menu - Load and Motor - Group
32
Main Menu - Brakes - Group
41
Main Menu-Reference/Ramps-Group
43
Main Menu - Limits/Warnings - Group
46
Main Menu - Digital In/Out - Group
49
Main Menu - Analog In/Out - Group
58
Main Menu - Communications and Options - Group
64
Main Menu - Smart Logic - Group
69
Main Menu - Special Functions - Group
77
Main Menu - Drive Information - Group
81
Main Menu - Data Readouts - Group
82
Main Menu - Data Readouts 2 - Group
86
Main Menu - FC Closed Loop - Group
87
Main Menu - Application Functions - Group
90
Main Menu - Application Functions 2 - Group
96
Main Menu - Special Features - Group
99
4 Troubleshooting
100
Introduction to Alarms and Warnings
100
Alarm Words
102
Warning Words
102
Extended Status Words
103
List of Warnings and Alarms
103
List of LCP Errors
106
Operation/Display
108
Load and Motor
108
Brakes
110
Reference/Ramps
110
Limits/Warnings
111
Digital In/Out
111
Analog In/Out
112
Comm. and Options
113
Smart Logic
114
Special Functions
114
Drive Information
115
Data Readouts
116
Info & Readouts
117
Drive Closed Loop
117
Appl. Functions
118
Appl. Functions
119
Special Features
119
Danfoss VLT HVAC Basic Drive FC 101 Programming Manual (104 pages)
Brand:
Danfoss
| Category:
DC Drives
| Size: 4 MB
Table of Contents
Table of Contents
3
1 Introduction
5
Purpose of the Manual
5
Document and Software Version
5
Safety Symbols
5
Safety Precautions
5
Additional Resources
6
Definitions
6
Electrical Overview
9
2 How to Programme
10
Programming with MCT 10 Setup Software
10
Local Control Panel (LCP)
10
Menus
11
Status Menu
11
Quick Menu
11
Start-Up Wizard for Open Loop Applications
11
Main Menu
20
Quick Transfer of Parameter Settings between Multiple Frequency Converters
20
Read-Out and Programming of Indexed Parameters
20
Initialise the Frequency Converter to Default Settings in Two Ways
20
3 Parameters
22
Main Menu - Operation and Display - Group
22
Main Menu - Load and Motor - Group
26
Main Menu - Brakes - Group
33
Main Menu - Reference/Ramps - Group
34
Main Menu - Limits/Warnings - Group
37
Main Menu - Digital In/Out - Group
40
Main Menu - Analog In/Out - Group
50
Main Menu - Communications and Options - Group
55
Main Menu - Smart Logic - Group
59
Main Menu - Special Functions - Group
67
Main Menu - Drive Information - Group
70
Main Menu - Data Readouts - Group
72
Main Menu - Data Readouts 2 - Group
76
Main Menu - FC Closed Loop - Group
76
Main Menu - Application Functions - Group
78
Main Menu - Application Functions 2 - Group
80
Alarms and Warnings
83
Alarm Words
85
Warning Words
85
Extended Status Words
86
List of Warnings and Alarms
86
5 Parameter Lists
89
Parameter Options
89
Default Settings
89
Operation/Display
90
Load and Motor
90
Brakes
92
Reference/Ramps
92
Limits/Warnings
92
Digital In/Out
93
Analog In/Out
94
Comm. and Options
95
Smart Logic
95
Special Functions
96
Drive Information
97
Data Readouts
97
Info & Readouts
98
Drive Closed Loop
99
Appl. Functions
99
Danfoss VLT HVAC Basic Drive FC 101 Operating Manual (84 pages)
Brand:
Danfoss
| Category:
DC Drives
| Size: 8 MB
Table of Contents
Table of Contents
3
1 Introduction
6
Purpose of this Operating Guide
6
Trademarks
6
Additional Resources
6
Other Resources
6
MCT 10 Setup Software Support
6
Document and Software Version
6
Certificates and Approvals
7
Disposal
8
2 Safety
9
Safety Symbols
9
Qualified Personnel
9
Safety Precautions
9
Motor Thermal Protection
11
3 Installation
12
Mechanical Installation
12
Side-By-Side Installation
12
Drive Dimensions
13
Electrical Installation
15
Electrical Installation in General
15
Mains
16
Mains and Motor Connection
18
Introduction
18
Connecting to Mains and Motor
19
Relays and Terminals on Enclosure Sizes
19
Relays and Terminals on Enclosure Size H6
20
Relays and Terminals on Enclosure Size H7
21
Relays and Terminals on Enclosure Size H8
21
Connecting to Mains and Motor for Enclosure Size H9
22
Relays and Terminals on Enclosure Size H10
25
Enclosure Size I2
26
Enclosure Size I3
27
Enclosure Size I4
28
IP54 Enclosure Sizes
29
Enclosure Size I6
29
Enclosure Size
31
Fuses and Circuit Breakers
31
Branch Circuit Protection
31
Short-Circuit Protection
31
Overcurrent Protection
31
Ul/Non-UL Compliance
31
Recommendation of Fuses and Circuit Breakers
32
EMC-Correct Electrical Installation
34
Control Terminals
36
Electrical Wiring
37
Acoustic Noise or Vibration
38
4 Programming
39
Local Control Panel (LCP)
39
Setup Wizard
40
Setup Wizard Introduction
40
Setup Wizard for Open-Loop Applications
42
Setup Wizard for Closed-Loop Applications
48
Motor Setup
55
Changes Made Function
60
Changing Parameter Settings
60
Accessing All Parameters Via the Main Menu
60
Parameter List
61
5 Warnings and Alarms
63
List of Warnings and Alarms
63
Danfoss VLT HVAC Basic Drive FC 101 Quick Manual (62 pages)
Brand:
Danfoss
| Category:
DC Drives
| Size: 4 MB
Table of Contents
Table of Contents
3
1 Introduction
5
Purpose of the Quick Guide
5
Additional Resources
5
Document and Software Version
5
Certificates and Approvals
5
Disposal
5
2 Safety
6
Introduction
6
Qualified Personnel
6
Motor Thermal Protection
7
3 Installation
8
Mechanical Installation
8
Side-By-Side Installation
8
Adjustable Frequency Drive Dimensions
9
Electrical Installation
11
Electrical Installation in General
11
IT Line Power
12
Connecting to Line Power and Motor
12
Fuses and Circuit Breakers
20
EMC-Compatible Electrical Installation
23
Control Terminals
25
Electrical Wiring
26
Acoustic Noise or Vibration
27
4 Programming
28
Local Control Panel (LCP)
28
Set-Up Wizard
29
Parameter List
43
5 Warnings and Alarms
46
6 Specifications
48
Line Power Supply
48
3X200-240 V AC
48
3X380-480 V AC
49
3X525-600 V AC
53
MG18A622 Danfoss A/S © 08/2014 All Rights Reserved
53
EMC Emission Test Results
54
Special Conditions
56
Derating for Ambient Temperature and Switching Frequency
56
Derating for Low Air Pressure and High Altitudes
56
General Technical Data
57
Protection and Features
57
Line Power Supply (L1, L2, L3)
57
Motor Output (U, V, W)
57
Cable Lengths and Cross-Sections
57
Digital Inputs
58
Analog Inputs
58
Analog Output
58
Digital Output
58
Control Card, RS-485 Serial Communication
59
Control Card, 24 V DC Output
59
Relay Output
59
Control Card, 10 V DC Output 1)
59
Ambient Conditions
59
Danfoss VLT HVAC Basic Drive FC 101 Quick Manual (58 pages)
VLT HVAC Basic Drive
Brand:
Danfoss
| Category:
Controller
| Size: 4 MB
Table of Contents
Table of Contents
3
1 Introduction
5
Purpose of the Quick Guide
5
Additional Resources
5
Document and Software Version
5
Certificates and Approvals
5
Disposal
5
2 Safety
6
Safety Symbols
6
Qualified Personnel
6
Motor Thermal Protection
7
3 Installation
8
Mechanical Installation
8
Side-By-Side Installation
8
Frequency Converter Dimensions
9
Electrical Installation
11
Electrical Installation in General
11
IT Mains
12
Connecting to Mains and Motor
13
Fuses and Circuit Breakers
19
EMC-Correct Electrical Installation
22
Control Terminals
23
Electrical Wiring
24
Acoustic Noise or Vibration
25
4 Programming
26
Local Control Panel (LCP)
26
Set-Up Wizard
27
Parameter List
39
5 Warnings and Alarms
42
6 Specifications
44
Mains Supply
44
3X200-240 V AC
44
3X380-480 V AC
45
3X525-600 V AC
49
EMC Emission Test Results
50
Special Conditions
51
Derating for Ambient Temperature and Switching Frequency
51
Derating for Low Air Pressure and High Altitudes
51
General Technical Data
52
Protection and Features
52
Mains Supply (L1, L2, L3)
52
Motor Output (U, V, W)
52
Cable Lengths and Cross Sections
52
Digital Inputs
53
Analog Inputs
53
Analog Output
53
Digital Output
53
Control Card, RS-485 Serial Communication
54
Control Card, 24 V DC Output
54
Relay Output
54
Control Card, 10 V DC Output 1)
54
Ambient Conditions
55
Index
56
Danfoss VLT HVAC Basic Drive FC 101 Quick Manual (56 pages)
HVAC Basic Drive
Brand:
Danfoss
| Category:
DC Drives
| Size: 4 MB
Table of Contents
Table of Contents
3
1 Introduction
5
Purpose of the Quick Guide
5
Additional Resources
5
Document and Software Version
5
Certificates and Approvals
5
Disposal
5
2 Safety
6
Safety Symbols
6
Qualified Personnel
6
Motor Thermal Protection
7
3 Installation
8
Mechanical Installation
8
Side-By-Side Installation
8
Frequency Converter Dimensions
9
Electrical Installation
11
Electrical Installation in General
11
IT Mains
12
Connecting to Mains and Motor
12
EMC-Correct Electrical Installation
21
Control Terminals
22
Acoustic Noise or Vibration
24
4 Programming
25
Local Control Panel (LCP)
25
Set-Up Wizard
26
Parameter List
40
5 Warnings and Alarms
43
6 Specifications
45
Mains Supply
45
3X200-240 V AC
45
3X380-480 V AC
46
3X525-600 V AC
50
EMC Emission Test Results
51
Special Conditions
51
Derating for Ambient Temperature and Switching Frequency
51
Derating for Low Air Pressure and High Altitudes
51
General Technical Data
51
Mains Supply (L1, L2, L3)
51
Motor Output (U, V, W)
51
Cable Length and Cross-Section
52
Digital Inputs
52
Analog Inputs
52
Analog Output
52
Digital Output
53
Control Card, RS485 Serial Communication
53
Control Card, 24 V DC Output
53
Relay Output
53
Control Card, 10 V DC Output
53
Ambient Conditions
54
Index
55
Danfoss VLT HVAC Basic Drive FC 101 Quick Manual (49 pages)
HVAC Basic Drive
Brand:
Danfoss
| Category:
DC Drives
| Size: 6 MB
Table of Contents
Table of Contents
2
Safety
4
Warnings
4
Safety Instructions
4
Introduction
5
Available Literature
5
Approvals
5
IT Line Power
5
Avoid Unintended Start
5
Disposal Instructions
6
Installation
6
Before Starting Repair Work
6
Side-By-Side Installation
6
Dimensions
7
Electrical Installation in General
9
Connecting to Line Power and Motor
10
Fuses
16
EMC-Compliant Electrical Installation
18
Control Terminals
20
Electrical Overview
21
Programming
22
Programming with the Local Control Panel (LCP)
22
The Start-Up Wizard for Open-Loop Applications
23
Warnings and Alarms
36
General Specifications
38
Line Power Supply 3 X 200-240 V AC
38
Line Power Supply 3 X 380-480 V AC
39
Line Power Supply 3 X 380-480 V AC
41
Line Power Supply 3 X 525-600 V AC
43
EMC Test Results
44
Special Conditions
48
Derating for Ambient Temperature and Switching Frequency
48
Derating for Low Air Pressure
48
Options for VLT HVAC Basic Drive FC101
48
Danfoss VLT HVAC Basic Drive FC 101 Quick Manual (49 pages)
Brand:
Danfoss
| Category:
DC Drives
| Size: 9 MB
Table of Contents
Table of Contents
3
Safety
4
Warnings
4
Safety Instructions
4
Introduction
5
Available Literature
5
Approvals
5
IT Line Power
5
Avoid Unintended Start
6
Disposal Instruction
6
Installation
6
Before Starting Repair Work
6
Dimensions
7
Electrical Installation in General
9
Connecting to Line Power and Motor
10
Fuses and Circuit Breakers
18
EMC-Compatible Electrical Installation
20
Control Terminals
21
Programming
23
Programming with the Local Control Panel (LCP)
23
The Start-Up Wizard for Open-Loop Applications
24
Main Menu Structure
34
Acoustic Noise or Vibration
36
Warnings and Alarms
36
General Specifications
38
Line Power Supply 3X200-240 V AC
38
Line Power Supply 3X380-480 V AC
39
Line Power Supply 3X525-600 V AC
43
Special Conditions
48
Derating for Ambient Temperature and Switching Frequency
48
Derating for Low Air Pressure
48
Options for VLT ® HVAC Basic Drive FC 101
48
MCT 10 Support
48
Danfoss VLT HVAC Basic Drive FC 101 Quick Manual (45 pages)
VLT HVAC Basic Drive FC 101
Brand:
Danfoss
| Category:
DC Drives
| Size: 3 MB
Table of Contents
Table of Contents
2
Safety
3
Warnings
3
Safety Instructions
3
Introduction
4
Available Literature
4
Approvals
4
IT Mains
4
Avoid Unintended Start
5
Disposal Instruction
5
Installation
5
Before Starting Repair Work
5
Side-By-Side Installation
5
Dimensions
6
Electrical Installation in General
7
Connecting to Mains and Motor
8
Fuses
14
EMC-Correct Electrical Installation
16
Control Terminals
18
Electrical Overview
19
Programming
20
Programming with the Local Control Panel (LCP)
20
The Start-Up Wizard for Open Loop Applications
21
Main Menu Structure
31
Warnings and Alarms
33
General Specifications
35
Mains Supply 3X200-240 V AC
35
Mains Supply 3X380-480 V AC
36
Mains Supply 3X380-480 V AC
38
Mains Supply 3X525-600 V AC
40
Special Conditions
44
Derating for Ambient Temperature and Switching Frequency
44
Derating for Low Air Pressure
44
Options for VLT ® HVAC Basic Drive FC 101
44
MCT 10 Support
44
Danfoss VLT HVAC Basic Drive FC 101 Operating Manual (4 pages)
HVAC Basic Drive
Brand:
Danfoss
| Category:
DC Drives
| Size: 0 MB
Advertisement
Related Products
Danfoss FC 100
Danfoss FC 102
Danfoss VLT Micro Drive FC 51 Series
Danfoss FCM 300 Series
Danfoss VLT AutomationDrive FC 302
Danfoss VLT AQUA Drive FC 202
Danfoss VLT Automation Drive FC 301 A1
Danfoss FCM 300 PROFIBUS
Danfoss FCD 300 PROFIBUS
Danfoss FC 202
Danfoss Categories
Controller
DC Drives
Thermostat
Control Unit
Air Compressor
More Danfoss Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL