Application Guide | iC2-Micro Frequency Converters
Selection number
Selection name
41
Below Reference, Low
42
Above Refefence, High
45
Bus Control
46
Bus Control, Timeout: On
47
Bus Control, Timeout: Off
55
Pulse Output
56
Heat Sink Cleaning Warning, High
60
Comparator 0
61
Comparator 1
62
Comparator 2
63
Comparator 3
64
Comparator 4
65
Comparator 5
70
Logic rule 0
71
Logic rule 1
72
Logic rule 2
73
Logic rule 3
74
Logic rule 4
75
Logic rule 5
80
SL digital output A
81
SL digital output B
160
No Fault
238
| Danfoss A/S © 2024.03
Selection description
This option is active when the actual speed is below the speed
reference setting.
This option is active when the actual speed is above the speed
reference setting.
Control output via fieldbus. The state of the output is set in P
9.4.6.1 Digital & Relay Bus Control. The output state is retained in
the event of fieldbus timeout.
Control output via fieldbus. The state of the output is set in P
9.4.6.1 Digital & Relay Bus Control. When bus timeout occurs, the
output state is set high (On).
Control output via fieldbus. The state of the output is set in P
9.4.6.1 Digital & Relay Bus Control. When bus timeout occurs, the
output state is set low (Off).
Use terminal 15 as pulse output.
Activated when the heat sink temperature is not lower than the
calculated value. The calculated value is equal to the maximum
value of P 2.1.9 Heat Sink Temperature minus the current value of
P 2.1.9 Heat Sink Temperature.
Use result of comparator 0 in logic rule.
Use result of comparator 1 in logic rule.
Use result of comparator 2 in logic rule.
Use result of comparator 3 in logic rule.
Use result of comparator 4 in logic rule.
Use result of comparator 5 in logic rule.
Use result of logic rule 0 in logic rule.
Use result of logic rule 1 in logic rule.
Use result of logic rule 2 in logic rule.
Use result of logic rule 3 in logic rule.
Use result of logic rule 4 in logic rule.
Use result of logic rule 5 in logic rule.
See P 8.4.6.2 Action. The output goes high whenever the smart
logic action [38] Set digital out A high is executed. The output
goes low whenever the smart logic action [32] Set digital out A
low is executed.
See P 8.4.6.2 Action. The output goes high whenever the smart
logic action [39] Set digital out B high is executed. The output
goes low whenever the smart logic action [33] Set digital out B
low is executed.
The output is high when no alarm is present.
AB413939445838en-000301 / 130R1254