Application Guide | iC2-Micro Frequency Converters
P 6.6.8 Operation Mode
Use this parameter to select the drive operation mode. To reset drive parameter values to default, select [2] Initialization. The
communication related parameters remain unchanged. The frequency converter resets during the next power-up.
Default value:
0 [Normal operation]
Parameter
1422
number:
Data type:
enum
The following are the selections for the parameter.
Selection number
0
2
P 6.6.9 Service Code
This parameter is intended for use by service technicians only.
Default value:
0
Parameter
1429
number:
Data type:
uint32
P 6.6.12 ECP Copy
Use this parameter to select the ECP copy functions.
Default value:
0
Parameter
50
number:
Data type:
enum
The following are the selections for the parameter.
Selection number
Selection name
0
No copy
1
All to ECP
2
All from ECP
3
Size indep. from ECP
Danfoss A/S © 2024.03
Parameter type:
Unit:
Access type:
Selection name
Normal operation
Initialization
Parameter type:
Unit:
Access type:
Parameter type:
Unit:
Access type:
Selection description
Do not copy any parameter.
Copy all parameters in all setups from drive to ECP.
Copy all parameters in all setups from ECP to drive.
Copy only parameters which are independent of motor size, w/o
disturbing motor data already set.
AB413939445838en-000301 / 130R1254 |
Selection
–
Read/Write
Range (0–4294967295)
–
Read/Write
Selection
–
Read/Write
195