ABB AC500 V3 Hardware Manual page 58

Hide thumbs Also See for AC500 V3:
Table of Contents

Advertisement

Device specifications
Processor modules > AC500-eCo
1
4 yellow LEDs to display the signal states of the inputs O0 to O3
2
Allocation of signal name
3
7-pin terminal block for output signals
Intended pur-
The device is used as an optional I/O extension module for AC500-eCo V3 CPUs (PM50x2).
pose
The inputs/outputs are group-wise galvanically isolated from each other.
All other circuitry of the module is galvanically isolated from the inputs/outputs.
Functionality
Parameter
LED displays
Internal power supply
External power supply
Connections
The connection is carried out by using a removable 7-pin terminal block. For more information,
please refer to the chapter terminal blocks for AC500-eCo V3 system. The terminal blocks are
included in the module's scope of delivery and additional terminal blocks as spare parts can be
ordered separately.
The following block diagram shows the internal construction of the digital outputs:
58
NOTICE!
Risk of damaging the PLC modules!
Overvoltages and short circuits might damage the PLC modules.
Make sure that all voltage sources (supply voltage and process supply
voltage) are switched off before you begin with operations on the system.
Never connect any voltages or signals to reserved terminals (marked with
"NC"). Reserved terminals may carry internal voltages.
For a detailed description of the mounting, disassembly and connection of the
module, please refer to the system assembly chapter.
3ADR010278, 3, en_US
Value
For signal states
Via internal CPU connection
Via the terminals ZP and UP (process supply
voltage 24 V DC)
2022/01/31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac500-eco v3Ac500-xc v3

Table of Contents