1.4.5.1.1
Intended purpose
The communication module is for PROFINET RT communication.
The PROFINET communication module includes an internal Ethernet switch. The connection to
the Ethernet can be established directly to the communication module. An additional switch is
not necessary.
The communication module is configured via the dual-port memory by means of a system
configurator. The configuration is saved on a non-volatile Flash EPROM memory.
For use in extreme ambient conditions (e.g. wider temperature and humidity range), a special
XC version of the device is available.
1.4.5.1.2
Functionality
Parameter
Protocol
Usable CPUs
Usable terminal bases
Field bus connector
Internal supply
1.4.5.1.3
Connections
Field bus interfaces
The communication module provides 2 RJ45 interfaces.
Pin assignment
Interface
2022/01/31
PIN
1
2
3
4
5
6
7
8
Shield
In corrosive environment, please protect unused connectors using the TA535
accessory.
Not supplied with this device.
3ADR010278, 3, en_US
Communication modules (AC500 standard) > PROFINET
Value
PROFINET IO RT
PM57x, PM58x, PM59x
Ä Chapter 1.3.2.1 "PM56xx-2ETH for AC500
V3 products" on page 90
All TB56xx (not TB5600)
"TB56xx for AC500 V3 products" on page 4
2 RJ45 (PNIO1 and PNIO2), with integrated
2-port switch
Via the communication module interface of the
terminal base
Signal
Description
TxD+
Transmit data +
TxD-
Transmit data -
RxD+
Receive data +
NC
Not connected
NC
Not connected
RxD-
Receive data -
NC
Not connected
NC
Not connected
Cable shield
Functional earth
Device specifications