Parameter
Common power supply voltage
Reference potential for the channels O0 to
O3
Indication of the output signals
Way of operation
Min. output voltage at signal 1
Output delay (max. at rated load)
Output data length
Output current
Max. leakage current with signal 0
Output type
Protection type
Rated protection fuse (for each channel)
Demagnetization when inductive loads are
switched off
Switching Frequencies
Short-circuit-proof / Overload-proof
Connection of 2 outputs in parallel
Max. cable length
2022/01/31
0 to 1
1 to 0
Rated current per channel (max.)
Rated current per group (max.)
With inductive loads
Overload message
Output current limitation
Resistance to feedback against 24 V
DC
Shielded
Unshielded
3ADR010278, 3, en_US
Processor modules > AC500-eCo
Value
Terminal 6 (positive pole of the process voltage,
signal name UP)
Terminal 7 (negative pole of the process voltage,
signal name ZP)
1 yellow LED per channel; the LED is on when
the output signal is high (signal 1).
Only internal logic is powered from CPU.
Outputs are powered from UP/ZP terminals.
Non-latching type
UP - 0.1 V
50 µs
200 µs
1 byte
0.5 A at UP 24 V DC (resistance, general use
and pilot duty)
2 A (4 channels * 0.5 A)
0.5 mA
Non-protected
External fuse on each channel
On request
Must be performed externally according to driven
load specification
On request
No
No
No
No
Not possible
On request
On request
Device specifications