Fig. 11: Connection of 100-240 V AC actuators
The module provides several diagnosis functions (see section Diagnosis
"Diagnosis" on page 239).
The meaning of the LEDs is described in the section State LEDs
LEDs" on page 229.
2022/01/31
L
120 V AC/
~
240 V AC
N
L
120 V AC/
~
240 V AC
N
+
24 V DC
-
3ADR010278, 3, en_US
Device specifications
I/O modules > Digital I/O modules
1
NO0
2
NO1
3 NO2
4 NO3
5 NO4
6 NO5
7 NO6
8 NO7
9 R0..7
10
NO8
11
NO9
12 NO10
13 NO11
14 NO12
15 NO13
16 NO14
17 NO15
18 R8..15
19 L+
20 M
Ä Chapter 1.6.1.1.11.6
Ä Chapter 1.6.1.1.10.7 "State
237