Mains Power Connection; Connection To The Mains Switch - ABB IRB 6400R Product On-Line Manual

Hide thumbs Also See for IRB 6400R:
Table of Contents

Advertisement

On-Site Installation

2.11 Mains power connection

Before starting to connect the mains, make sure that the other end of the cable is
disconnected from the line voltage.
The power supply can be connected either inside the cabinet, or to a optional socket on
the left-hand side of the cabinet or the lower section of the front. The cable connector
is supplied but not the cable. The mains supply cables and fuses should be dimensioned
in accordance with rated power and line voltage, see rating plate on the controller.

2.11.1 Connection to the mains switch

Remove the left cover plate under the top lid. Pull the mains cable (outer diam. 10.20
mm) through the gland (see Figure 21), located on the left cabinet wall.
Cable gland
Figure 21 Mains connection inside the cabinet.
Connect as below (also see chapter 11, Circuit Diagram.):
1. Release the connector from the knob by pressing in the red button located on the
upper side of the connector (see Figure 21).
2. Connect phase
and protective earth to
NOTE!
Max. cunductor size is 6 mm
Retighten after approx. 1 week.
3. Snap the breaker on to the knob again and check that it is fixed properly in the right
position.
4. Tighten the cable gland.
5. Fasten the cover plate.
28
XT 26
PE
1 to L1 (N.B. Not dependent on phase sequence)
2 to L2
3 to L3
0 to XT26.N(line neutral is needed only for option 432)
Installation and Commissioning
Connector
2
(AWG 10). Tighten torque 2.3-2.5 Nm.
Product Manual IRB 6400

Advertisement

Table of Contents
loading

Table of Contents