2. INSTALLATION

2-1. Installing the AW-3S

For details, refer to the "Retrofit Instructions for the AW-3SB" in the case of installing the AW-3S to the
AMS-221EN or "Retrofit Instructions for the AW-3SC" in the case of installing it to the AMS-224EN.

2-2. Installation location

For the installation location, carefully check the following points.
(1) This device uses an optical sensor. In order to protect the optical sensor from malfunctioning, do
not install the device near a window or in any other location where it is likely to be exposed to direct
sunlight. Alternatively, install the device in a direction where it will not be exposed to direct sunlight.
(2) In order to avoid malfunctioning, do not use the device near any equipment that generates large
electrical noise. In addition, it is preferable to keep the power supply line away from the aforemen-
tioned equipment.
2-3. Installing the bobbin thread remaining amount detection sensor
(optional)
DANGER :
1. There will be a risk of vision impairment if laser light directly enters the eye. Do not look into the
laser output port.
2. Never attach/remove the sensor unit with the power remained ON. In addition, do not use the
sensor for any purpose other than for detecting the bobbin thread remaining amount.
For details, refer to the "Retrofit Instructions for the AW-3SB" in the case of installing the AW-3S to the
AMS-221EN or "Retrofit Instructions for the AW-3SC" in the case of installing it to the AMS-224EN.
Temporarily secure bobbin thread remaining
amount detection sensor unit ❶ to base ❷ with
supplied screws ❸ .
Specifications of the bobbin thread remaining
amount detection sensor
Class 2 sensor product
Maximum output : 1mW
Wave length : 655 nm (red)
Safety standards
JIS / IEC60825-1 2014