4-2. Replacing the CCD Camera and Lens

(1) Detach the camera assembly from the XM base using the procedure described in section 4-1,
Replacing the OCC Assembly.
(2) Remove the screws fixing the CCD camera and lens to replace the CCD camera and lens.
(3) Reassemble the components in the reverse order of disassembly. (Apply Loctite242 to the
round screws.)
(Apply Loctite 242 to the round screws and SEMS cap bolts, and then fix them with a tightening
torque of 1.0Nm.)
(4) After the CCD camera and lens have been replaced, adjust the focus and input the MS
parameters. (See 4-7, List of Readjustment Items After Replacement.)
Hexagon socket head
cap bolt (× 4)
CCD camera
Lens
Figure 4-2-1 CCD Camera/Lens
4-2
Round screw (× 2)
Apply Loctite242.
SEMS cap bolts
(× 2)
Apply Loctite 242.