4-2. Replacing the CCD Camera and Lens
(1) Detach the camera assembly from the head plate using the procedure described in section
4-1, Replacing the OCC Assembly.
(2) Remove the fixing screws securing the CCD camera and lens, and replace the CCD camera
and lens.
(3) Reassemble the components in the reverse order of disassembly.
(Apply Loctite 242 to each screw and tighten it with a tightening torque.)
(4) After the CCD camera and lens have been replaced, adjust the focus and input the MS
parameters. (See 4-8, List of Readjustment Items After Replacement.)
Hexagon socket
head cap bolt ( 4)
Apply Loctite 242.
Tightening torque of
0.3 N m
CCD camera
Lens
Maintenance Guide
Figure 4-2-1 CCD Camera/Lens
4-2
Round screw ( 2)
Apply Loctite 242.
Tightening torque
of 1.0 N m
SEMS cap bolts
( 2)
Apply Loctite 242.
Tightening torque
of 1.0 N m