– Turn the assembly sleeve - T10133/6- in order to slide the
combustion chamber sealing ring onto the assembly cone -
T10133/5- up to the end.
– Remove the assembly cone - T10133/5- and slide the com‐
bustion chamber sealing ring with assembly sleeve -
T10133/6- up to the sealing ring groove.
– Press calibrating sleeve -T10133/7- with a gentle rotary move‐
ment (approximately 180°) up to the stop on the injector.
– Remove the calibrating sleeve -T10133/7- through the reverse
direction of rotation again.
– Press calibrating sleeve -T10133/8- with a gentle rotary move‐
ment (approximately 180°) up to the stop on the injector.
– Remove the calibrating sleeve -T10133/8- through the reverse
direction of rotation again.
– Replace O-ring for injection valve. Before installing, wet O-ring
with clean engine oil.
– Before installation of the injection valves, clean the bore holes
of the high-pressure injection valves in the cylinder head with
the nylon brush - T10133/4- .
Note
The Teflon gasket ring of the injection valve must neither be
oiled nor greased.
When installing the injection valves, there should be no clean‐
ing agents or oil in the bores in the cylinder head.
– Press the injector valve into the cylinder head bore (free of oil
and grease) by hand up to the stop. Pay attention to the correct
position of the injection valves in the cylinder head.
Octavia III 2013 ➤ , Octavia III 2014 ➤
1.8/132 kW TSI; 2.0/162 kW TSI engines - Edition 01.2015
303
4. Injection valves

Advertisement