WGMODE[2:0] Group Configuration Mode of Operation Top
100
101
110
111
DSBOTTOM
Value
Name
0x0
NORMAL
0x1
FRQ
0x3
SINGLESLOPE
0x5
DSTOP
0x6
DSBOTH
0x7
DSBOTTOM
Other
-
©
2018 Microchip Technology Inc.
-
Reserved
DSTOP
Dual-slope PWM
DSBOTH
Dual-slope PWM
Dual-slope PWM
Description
Normal operation mode
Frequency mode
Single-slope PWM mode
Dual-slope PWM mode
Dual-slope PWM mode
Dual-slope PWM mode
Reserved
Datasheet Preliminary
megaAVR
16-bit Timer/Counter Type A (TCA)
Update
OVF
-
-
-
PER
BOTTOM TOP
PER
BOTTOM TOP and BOTTOM
PER
BOTTOM BOTTOM
DS40002015A-page 201
®
0-Series
Need help?
Do you have a question about the megaAVR 0 Series and is the answer not in the manual?