Esc+Ys Format Registration - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

14.8 Memory Card
14.8

ESC+YS Format Registration

Format Registration
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Registering print format.
[Format]
<YS>,aaa
●Parameter
a [Format registration number]
[Coding Example]
<A>
<CC>1
<YS>,1
</N>,3,3
<%>0<V>100<H>200<P>2<L>0101<XM>ABC
<Z>
[Supplementary Explanation]
1. When registering multiple formats, Delimit Start of Data Transmission <A> and End of Data Transmission <Z> with
one format.
2. Specify Card Slot for Use <CC> prior to this command when using.
3. Use this command and Registration of Field </N> as a pair.
4. Attempts to re-register with registered No., error will occur, and the targeted content will be printed.
5. The error occurs when specifying unused or specifying the slot which the printer is allocated.
[Notes]
1. Do not turn off the printer while accessing the memory. When the printer power is off while memory accessing, the
data in the accessed media may be corrupted.
2. The maximum registration with </N> is 99 fields. (Refer to the customizable print command of the field
registration(ESC+/N) for the commands can be registered.)
3. The maximum registration with other than </N> is 50 fields. Refer to the customizable print command for the
commands can be registered.)
YS
Parameter
<59>
<53>
,aaa
16
16
The set parameter is not maintained.
The set parameter is valid until the next valid setting.
The set parameter is valid until the next valid setting.
=
Valid Range
:
289
ESC+YS
1 to 999