Esc+Tw Option Waiting Time - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

12.24 System
12.24

ESC+TW Option Waiting Time

Option Waiting Time
ESC
Hexadecimal
code
<1B>
16
Initial value
aaa = 000
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Specifies waiting time for optional device
[Format]
<TW>aaa
●Parameter
aaa
[Waiting time]
[Coding Example] (waiting time = 1.5 seconds)
<A>
<TW>015
<Z>
[Supplementary Explanation]
1. This command specifies, in Tear-off mode, the waiting time between print completion and Tear-off motion.
2. The set parameter becomes valid soon after receiving the command and will be retained after power off.
TW
Parameter
<54>
<57>
aaa
16
16
The set parameter is maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
=
Valid range: 000, 005 to 200 (unit: 100ms)
275
ESC+TW

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents