HT32F52220/HT32F52230
Bits
Field
[1]
ITADF
[0]
ORFF
Rev. 1.10
Descriptions
Invalid Target Address Flag
0: The target address is valid
1: The target address is invalid
The data in the TADR field must be in the range from 0x0000_0000 to 0x1FFF_
FFFF. Otherwise, an ITAD interrupt will occur if the ITADIEN bit in the OIER register
is set. Reset this bit by writing 1.
Operation Finished Flag
0: No flash operation is finished
1: Last Flash operation is finished
The ORF interrupt will occur if the ORFIEN bit in the OIER register is set. Reset this
bit by writing 1.