System Clock (Ck_Sys) Selection - Holtek HT32F52220 User Manual

32-bit microcontroller with arm cortex-m0+ core
Table of Contents

Advertisement

32-Bit Arm
®
Cortex
®
-M0+ MCU
HT32F52220/HT32F52230

System Clock (CK_SYS) Selection

After the system reset occurs, the default system clock source, CK_SYS, will be the high speed
internal RC oscillator, HSI. The CK_SYS may come from the HSI, HSE, LSI or PLL output clock
and it can be switched from one clock source to another by configuring the System Clock Switch
bits SW in the Global Clock Control Register, GCCR. The system will still run under the original
clock until the destination clock gets ready when the SW value is changed. The corresponding
clock ready status bits in the Global Clock Status Register GCSR will indicate whether the selected
clock is ready to use or not. The CKCU also contains the clock source status bits in the Clock
Source Status Register CKST to indicate which clock is currently used as the system clock. If a
clock source or the PLL output clock is used as the system clock source, it is not possible to stop it.
More details about the clock enable function are described in the following .
If any event in the following occurs, the HSI will be enabled .
Enable PLL and configure its source clock to HSI. (PLLEN, PLLSRC)
Enable Clock monitor. (CKMEN)
Configure clock switch register to HSI. (SW)
Configure HSI enable register to 1. (HSIEN)
If any event in the following occurs, the HSE will be enabled.
Enable PLL and configure its source clock to HSE. (PLLEN, PLLSRC)
Configure clock switch register to HSE. (SW)
Configure HSE enable register to 1. (HSEEN)
If any event in the following occurs, the PLL will be enabled.
Enable USB Enable register. (USBEN)
Configure clock switch register to PLL (SW)
Configure PLL enable register to 1. (PLLEN)
The system clock selection programming guide is listed in the following.
1. Enable any clock source which will become the system clock or PLL input clock.
2. Configuring the PLLSRC register will has no operation until the ready flags of both HSI and
HSE are asserted.
3. Configuring the SW register to change the system clock source will take effect after the
corresponding ready flag of the clock source is asserted. Note that the system clock will be
forced to HSI if the clock monitor is enabled and the PLL output clock or HSE clock configured
as the system clock is stuck at 0 or 1.
Rev. 1.10
75 of 366
November 09, 2018