Fr Inarp Interval - H3C MSR810 Command Reference Manual

Msr router series comware 7 layer 2 - wan access
Hide thumbs Also See for MSR810:
Table of Contents

Advertisement

Predefined user roles
network-admin
Parameters
ip: Performs inverse address resolution for IPv4 addresses.
dlci-number: Specifies a VC by its DLCI number. The value range for this argument is 16 to 1007. If
you do not specify a VC, all VCs on the interface and on all its subinterfaces are specified.
Usage guidelines
When Frame Relay sends data over an interface, the peer IP addresses must be mapped to the local
DLCIs. The address-to-DLCI mapping can be configured automatically through InARP or manually.
If you enable or disable InARP on a Frame Relay interface without specifying a VC, InARP is enabled
or disabled on the following VCs:
All VCs on the Frame Relay interface.
All VCs on each subinterface of the Frame Relay interface.
Examples
# Enable InARP on all VCs of the Frame Relay interface Serial 2/1/0.
<Sysname> system-view
[Sysname] interface serial 2/1/0
[Sysname-Serial2/1/0] fr inarp ip
Related commands
display fr inarp

fr inarp interval

fr inarp interval
Use fr inarp interval to set the InARP request interval during an InARP learning process.
Use undo fr inarp interval to restore the default.
Syntax
fr inarp interval interval
undo fr inarp interval
Default
The InARP request interval during an InARP learning process is 60 seconds.
Views
Interface view
Predefined user roles
network-admin
Parameters
interval: Specifies the InARP request interval during an InARP learning process. The value range for
this argument is 15 to 300 seconds.
Usage guidelines
The InARP request interval takes effect only when InARP is enabled.
340

Hide quick links:

Advertisement

Table of Contents
loading