Usage guidelines
This command is applicable only to outbound PVCs.
Examples
# Set the CLP flag value of ATM cells to 1.
<Sysname> system-view
[Sysname] traffic behavior database
[Sysname-behavior-database] remark atm-clp 1
reset atm interface
Use reset atm interface to clear PVC statistics.
Syntax
reset atm interface [ interface-type { interface-number | interface-number.subnumber } ]
Views
User view
Predefined user roles
network-admin
Parameters
interface-type { interface-number | interface-number.subnumber }: Clears statistics about all PVCs
(including PVCs on the interface and PVCs of the PVC-groups) for the specified interface. Both ATM
interfaces and ATM subinterfaces are supported. If you do not specify an interface, this command
clears statistics about all PVCs for all interfaces.
Usage guidelines
This command clears statistics only about PVCs. To clear statistics about interfaces, use the reset
counters interface command.
Examples
# Clear statistics about all PVCs for the interface ATM 2/4/0.
<Sysname> reset atm interface atm 2/4/0
reset counters interface virtual-ethernet
Use reset counters interface virtual-ethernet to clear VE interface statistics.
Syntax
reset counters interface [ virtual-ethernet [ interface-number ] ]
Views
User view
Predefined user roles
network-admin
Parameters
virtual-ethernet: Clears the statistics for a VE interface.
interface-number: Specifies a VE interface by its number.
222