Jog Operation - Delta ASD-B2-0121-B User Manual

Asda-b2 series standard type ac servo drive for network communication application
Hide thumbs Also See for ASD-B2-0121-B:
Table of Contents

Advertisement

Chapter 4 Display and Operation

4.4.2 JOG Operation

After entering parameter mode P4-05, the users can follow the following steps to perform
JOG operation. (Please also refer to Figure 4.4).
Step1. Press the SET key to display the JOG speed. (The default value is 20 r/min).
Step2. Press the UP or DOWN arrow keys to increase or decrease the desired JOG speed.
(This also can be undertaken by using the SHIFT key to move the cursor to the
desired unit column (the effected number will blink) then changed using the UP
and DOWN arrow keys. The example display in Figure 4.4 is adjusted as 100
r/min.)
Step3. Press the SET key when the desired JOG speed is set. The Servo Drive will display
"JOG".
Step4. Press the UP or DOWN arrow keys to jog the motor either CCW or CW. The motor
will only rotate while the arrow key is activated.
Step5. To change JOG speed again, press the MODE key. The servo Drive will display "P4 -
05". Press the SET key and the JOG speed will displayed again. Refer back to #2
and #3 to change speed.
NOTE
1) JOG operation is effective only when Servo On (when the servo drive is enabled).
Figure 4.4
4-8
Revision June 2010

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents