Vertical Path Duplex Motor; Pickup Motor (M12) - Canon Image Reader-A1 iR5000i Service Manual

Photocopy machines
Hide thumbs Also See for Image Reader-A1 iR5000i:
Table of Contents

Advertisement

CHAPTER 7 EXTERNALS AND CONTROLS
5.7.3 Vertical Path Duplex Motor (M25), Vertical Path Upper Motor (M26),
Deck Right Motor (M11), Lifter Right Motor (M5), and Cassette

Pickup Motor (M12)

1) Remove the main controller box.
2) Remove the right rear lower cover, rear
lower cover, an waste toner bottle.
3) By referring to step 3) for the main mo-
tor, remove the main power switch base
out of the way.
4) Remove the two screws [1], and discon-
nect the two connectors [2]; then, de-
tach the connector base [3].
5) Remove the three screws [4], and detach
the waste toner bottle holder [5].
Take care not to let the waste
toner go astray.
6) Remove the three screws [6], and dis-
connect the connector [7]; then, detach
the vertical path duplex motor [8].
7) Remove the two screws [9], an discon-
nect the connector [10]; then, detach the
vertical path upper motor [11].
8) Remove the two screws [12], and dis-
connect the connector [13]; then, detach
the deck right motor [14].
7-44 P
COPYRIGHT © 2001 CANON INC.
[2]
F07-507-04
[4]
[5]
F07-507-05
[8]
[6]
[7]
[9]
[11][10][12] [14] [13]
F07-507-06
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
[3]
[1]
[4]
[6]
[12]