1.4 Self Diagnosis of the Saddle Stitcher

E5F0
Main Cause
The paper positioning plate home position sensor (PI7S) is faulty. The pa-
per positioning plate motor (M4S) is faulty. The saddle stitcher controller
PCB is faulty.
Mode of
Detection
0001 The paper positioning plate home position sensor does not turn on
0002 The paper positioning plate home position sensor does not turn off
E5F1
Main Cause
The folding motor clock sensor (PI4S) is faulty. The paper folding home
position sensor (PI21S) is faulty. The folding motor (M2S) is faulty. The
saddle stitcher controller PCB is faulty.
Mode of
Detection
0001 The number of detection pulses of the folding motor clock sensor
0002 The state of the paper folding home position sensor does not
E5F2
Main Cause
The guide home position sensor (PI13S) is faulty. The guide motor (M3S)
is faulty. The saddle stitcher controller PCB is faulty.
Mode of
Detection
0001 The guide home position sensor does not turn on when the guide
0002 The guide home position sensor does not turn off when the guide
6-18 T
when the paper positioning plate motor has been driven for about
1.3 secs.
1 sec after the paper positioning plate motor has been driven for 1
sec.
drops below a specific value.
change when the folding motor has been driven for 3 secs.
motor has been driven for about 0.5 sec.
motor has been driven for 1 sec.