3) Disconnect the compartment from the
deck. (See p. 8-27P.)
4) Disconnect the connector [5], and re-
move the five screws [6]; then, detach
the deck lifter motor unit [7].
3.3.4 Removing the Lifter Cable (front of the deck)
1) Open the compartment of the deck, and
remove all paper.
2) Remove the screw, and detach the paper
rear end guide plate from inside the
compartment.
3) Push down the sensor lever [1] of the
paper supply position sensor inside the
compartment to move down the lifter
until the left/right hole in the compart-
ment side plate and the left/right hole in
the lifter match; then, insert two long
screwdrivers to hold the lifter in posi-
tion.