Adjusting The Pressure Of The Separation Roller - Canon Image Reader-A1 iR5000i Service Manual

Photocopy machines
Hide thumbs Also See for Image Reader-A1 iR5000i:
Table of Contents

Advertisement

3) Disengage the hook [4] of the separa-
tion roller assembly, and detach the
separation roller [5].

9.1.6 Adjusting the Pressure of the Separation Roller

1) Remove the right upper cover.
2) Remove the upper guide [1].
3) If double feeding or pickup failure oc-
curs during pickup, adjust the position
of the pressure spring of the separation
roller.
If double feeding occurs, remove the
mounting screw [2], and shift down the
mounting base [3]; then, fix it in hole A
using a mounting screw [2].
If pickup failure occurs, remove the
mounting screw [2], and shift the
mounting base [3] up; then, fix it in
hole B using a mounting screw [2].
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 5 PICK UP/FEEDING SYSTEM
[5]
F05-901-07
F05-901-08
Hole A
Hole B
F05-901-09
[4]
[1]
[2]
[3]
5-51 P