3.5 Controlling Transfer Charging

3.5.1 Outline

The system used to control transfer charging serves the following functions:
1. Controlling the DC bias to a specific level of current.

2. Controlling the output to suit the environment (fuzzy control).

The following shows the construction of the control system related to the transfer charg-
ing control system.
J102A
1
2
3
4
TR-LEAK-DETECT [1]
5
6
7
8
9
10
11
TR-CNT [2]
12
13
14
15
PR/TR-REMOTE [3]
16
The system uses the following signals:
[1] transfer charging leakage detection signal; '0' when an excessively high or low current
is detected.
[2] transfer charging current control signal; when about 3 V or higher and lower than 11 V,
the output of the transfer current turns ON; when about 12 V or higher, it turns OFF.
[3] high-voltage remote signal; turns on/off the transfer current output.
COPYRIGHT © 2001 CANON INC.
J4502
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
F04-305-01
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 4 IMAGE FORMATION SYSTEM
The transfer current varies
as follows in keeping with
the potential of TR-CNT.
400µA
100µA
T4505
3V
11V 12V
TR -CNT
Transfer
charging wire
4-27 P