CHAPTER 4 IMAGE FORMATION SYSTEM
9) Holding the grip [8] of the process unit
as indicated, take it out.

7.3.2 Mounting the Process Unit

Mount the process unit by reversing the steps used to remove it with the following in
mind:
1) On the left rail, place the process rail
along the guide plate [1] at the front/
rear of the rail. (See p.7-30P)
On the right rail [2], place the process
unit on the L-shaped stay.
2) After sliding the process unit into the
machine, match the slot in the drum
shaft and the slot in the drum using the
drum rotating tool [3]. Then, insert the
drum fixing tool [4], and fit the mount-
ing screw [5] into the center opening of
the drum rotating tool; then, tighten the
mounting screw.
4-56 P
COPYRIGHT © 2001 CANON INC.
F04-703-04
F04-703-05
[3]
[5]
F04-703-06
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
[8]
[1]
[2]
[4]