b. Operation
In the case of the right/left deck, two sensors are used to detect the position of the deck
base plate, and the level of paper is identified with reference to the state of the sensors (on/
off).
The absence of paper is detected by an exclusive sensor (See 2.2.3 "Detecting the Pres-
ence/Absence of Paper").
Paper level
100% to about 50%
about 50% to about 10%
about 10% or less
absent
COPYRIGHT © 2001 CANON INC.
F05-202-07
Right deck
[1]
[2]
Sensor
Sensor
(PS47)
(PS48)
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
T05-202-03
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 5 PICK-UP/FEEDING SYSTEM
[1]
[2]
Paper level
Paper level
(100% to
(about 50%
about 50%)
to about 10%)
[1]
Sensor
Sensor
(PS7)
(PS49)
ON
ON
ON
OFF
ON
OFF
OFF
OFF
[1]
[1]
[2]
[2]
Paper level
(about 10%
or less)
Left deck
[2]
Sensor
Sensor
(PS50)
(PS11)
ON
ON
ON
ON
OFF
ON
OFF
OFF
5-15 P