Temperature Control By Mode - Canon Image Reader-A1 iR5000i Service Manual

Photocopy machines
Hide thumbs Also See for Image Reader-A1 iR5000i:
Table of Contents

Advertisement

3.2.2 Temperature Control by Mode

a. Down Sequence (text mode)
If the main thermistor (TH1) of the fixing upper roller detects any of the following levels
of temperature, the machine increases the sheet-to-sheet interval to maintain a specific fixing
temperature so as to prevent faulty fixing in continuous printing mode.
Model
Control
temperature
Control
temperature
COPYRIGHT © 2001 CANON INC.
iR5000i Down Sequence
50 cpm return mode
40 cpm mode
35 cpm mode
print stop
T06-302-04
iR6000i Down Sequence
60 cpm return mode
50 cpm mode
40 cpm mode
print stop
T06-302-05
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 6 FIXING SYSTEM
100-V
120/230-V
170°C
175°C
165°C
170°C
160°C
165°C
155°C
160°C
175°C
170°C
165°C
160°C
6-15 P