16.7 Disassembly and Replacement
[A] ADU maintenance position
Note:
The removal of the transfer belt unit or the 2nd transfer unit can be easily performed at the ADU
maintenance position without taking off the automatic duplexing unit (ADU). When the ADU is at
its maintenance position, do not close the ADU because it may be damaged.
(1)
Open the automatic duplexing unit.
(2)
Remove 1 screw of the front hinge, and then
take off the automatic duplexing unit by lifting
it up slightly and sliding it to the rear side.
(3)
When installing, match the front and rear
hinge holes of the equipment and the right
and left hinge bosses of the ADU.
May 2006 © TOSHIBA TEC
Screw
Fig. 16-8
Fig. 16-9
e-STUDIO2500c/3500c/3510c AUTOMATIC DUPLEXING UNIT (ADU)
16 - 13
Automatic duplexing unit
Hole
Boss
Automatic duplexing unit
16