[C-2]
Main charger assembly
(1)
Take off the cleaning unit.
P.11-12 "[C-1] Cleaning unit/ Developer
unit"
(2)
Hold (A) part on the front side of the main
charger assembly, lift the cleaner case up
and take off the main charger assembly.
Notes:
Be sure not to touch, spit or scratch on
the drum surface.
Avoid a direct sunlight onto the drum.
Move it to a dark place as soon as it is
taken off.
[C-3]
Main charger cleaner
(1)
Take off the main charger assembly.
P.11-13 "[C-2] Main charger assembly"
(2)
Remove the main charger cleaner rod from
the guide.
(3)
Turn the main charger cleaner rod for 90
degrees to take it off.
Note:
Be sure to insert the main charger cleaner
rod all the way in before turning it 90
degrees, otherwise the needle electrodes
may be damaged.
May 2006 © TOSHIBA TEC
Cleaner case
Main charger assembly
Fig. 11-16
Guide
Fig. 11-17
Needle electrode
Main charger cleaner
Fig. 11-18
e-STUDIO2500c/3500c/3510c PROCESS UNIT RELATED SECTION
11 - 13
A
Main charger
cleaner rod
Main charger
cleaner rod
Main charger
cleaner rod
11