[A-2]
Transfer belt cleaning blade
(1)
Take off the transfer belt cleaning unit.
P.13-11 "[A-1] Transfer belt cleaning unit"
(2)
Remove 2 screws, and then take off the
transfer belt cleaning blade.
(3)
Remove 2 screws, and then take off the
recovery plate.
(4)
Remove the blade seals (both front and rear
sides).
Notes:
1. When the blade seals are being attached,
attach them on the position shown in the
figure (by slightly pushing it to the direc-
tion of the arrow).
2. After the blade seals have been attached,
be sure that no gap is left between the
blade seals and the edge of the transfer
belt cleaning blade.
May 2006 © TOSHIBA TEC
/ Blade seal
Transfer belt
cleaning blade
Blade seal
13 - 13
Recovery plate
Fig. 13-9
Blade seal
Transfer belt
cleaning blade
Blade seal
Transfer belt
cleaning blade
Fig. 13-10