[B-8]
1st transfer roller status detection sensor-2 (S15)
(1)
Take off the 2nd transfer facing roller and
2nd transfer facing roller cleaning mylar.
P.13-20 "[B-5] 2nd transfer facing roller /
2nd transfer facing roller cleaning mylar"
(2)
Remove 2 screws, and then take off the 2nd
transfer facing roller cleaner.
(3)
Remove the seal.
(4)
Release the latch and disconnect the con-
nector to take off the 1st transfer roller status
detection sensor.
[C] 2nd transfer unit (TRU)
[C-1]
2nd transfer unit (TRU)
(1)
Move the automatic duplexing unit to its
maintenance position.
P.16-13 "[A] ADU maintenance position"
(2)
Take off the right front hinge cover.
P.2-33 "[N] Right front hinge cover"
(3)
Remove 1 screw and take off the connector
cover.
e-STUDIO2500c/3500c/3510c TRANSFER UNIT
2nd transfer facing roller
clinging holder
Seal
Connector
1st transfer roller status detection sensor
13 - 24
Fig. 13-40
Fig. 13-41
Connector cover
Fig. 13-42
May 2006 © TOSHIBA TEC