Note:
When replacing the drum cleaning unit,
check if there is no gap between the blade
and pad on both ends. If there is, or when the
pads put pressure to the cleaning blade,
reattach the pads on the position shown in
the figure (by slightly pushing them to the
direction of the arrows).
[C-8]
Drum thermistor (THM1, THM2)
The drum thermistors are installed in the process units (EPU (Y) and EPU(K)).
•
Process unit (EPU (Y)): Drum thermistor (THM1)
•
Process unit (EPU (K)): Drum thermistor (THM2)
(1)
Take off the corresponding process unit, and
then take off the developer unit.
P.11-10 "[A] Process unit (EPU)"
P.11-12 "[C-1] Cleaning unit/ Developer
unit"
(2)
Remove 1 screw and take off the drum ther-
mistor.
e-STUDIO2500c/3500c/3510c PROCESS UNIT RELATED SECTION
Felt
Blade
Felt
Blade
11 - 18
Drum cleaning blade
Fig. 11-31
Drum thermistor
Fig. 11-32
May 2006 © TOSHIBA TEC