(4)
Remove 2 screws and take off the TRU
guide assembly.
(5)
Remove 2 screws and take off the TRU earth
plate.
[D] 2nd transfer roller position detection sensor (S29)
(1)
Take off the paper dust holder.
P.10-40 "[Q] Paper dust holder"
(2)
Disconnect the connector, release the latch
and take off the 2nd transfer roller position
detection sensor.
e-STUDIO2500c/3500c/3510c TRANSFER UNIT
TRU earth plate
13 - 28
TRU guide assembly
Fig. 13-52
Fig. 13-53
2nd transfer roller
position detection
sensor
Connector
Fig. 13-54