Note:
When the retainer installed on the drum shaft
has been taken off, be sure to install it while
aligning the direction of the ribs of the cou-
pling with the pin on the drum shaft.
Note:
When installing the drum, not use a patting powder.
Install the drum, shaft and sleeve by means of the following procedure.
1. Install the drum to the cleaner case with
its front side boss aligned with the seal on
the case. Be careful not to have the seal
on the rear side come off of the drum.
e-STUDIO2500c/3500c/3510c PROCESS UNIT RELATED SECTION
Retainer
Pin
Drum shaft
Drum
Gear
Seal
11 - 16
Rib
Coupling
Fig. 11-25
Boss
Seal
Fig. 11-26
Drum
Fig. 11-27
May 2006 © TOSHIBA TEC