(4)
Remove 2 C-rings and 2 fuser belt guides
from the heat roller.
Notes:
When insaling the fuser belt guide and C-
ring, be sure of the folowing.
Be sure that the fuser belt guide is placed
with its flat face inside contacting the
fuser belt (with the mold mark outside).
Check that the fuser belt guide is securely
fitted in the groove of the heat roller.
Check that the C-ring is also securely fit-
ted in the groove of the fuser belt guide
and avoid the convex portion.
[A-10] Pressure roller thermostat (THMO3)
(1)
Take off the front side cover and transport
guide.
P.15-18 "[A-2] Front side cover"
P.15-19 "[A-5] Transport guide"
(2)
Front side: Release the harness out of the 1
clamp, and then disconnect the 1 relay con-
nector.
(3)
Rear side: Release the harness out of the 5
clamps, and then disconnect the 1 relay con-
nector and 1 connector.
e-STUDIO2500c/3500c/3510c FUSER UNIT / PAPER EXIT SECTION
Fuser belt guide
C-ring
Fuser belt guide
C-ring
Protrusion
Clamp
15 - 26
Heat roller
Fuser belt guide
C-ring
Fig. 15-35
Clamp
Relay connector
Fig. 15-36
Clamp
Connector
Relay connector
Fig. 15-37