Toshiba e-STUDIO2500c Service Manual page 252

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO2500c:
Table of Contents

Advertisement

[E] Needle electrode cleaner detection sensor (S21)
(1)
Take off the shutter unit.
P.8-14 "[C] Shutter unit"
(2)
Take off the duct of the discharge LED (ERS-
K).
P.11-19 "[D] Discharge LED (ERS-Y,
ERS-M, ERS-C, ERS-K)"
(3)
Disconnect 1 connector. Release the latch,
and take off the needle electrode cleaner
detection sensor.
[F] Drum drive unit
(1)
Take off the ozone exhaust duct.
P.12-30 "[N] Ozone exhaust duct"
(2)
Remove 1 screw on the right side of the
drum drive unit.
(3)
Open the board case.
P.2-43 "[K] Board case"
(4)
Release the harness from the 3 harness
clamps.
(5)
Disconnect the 1 connector and 2 relay con-
nectors.
(6)
Remove 3 screws and take off the drum
drive unit.
e-STUDIO2500c/3500c/3510c PROCESS UNIT RELATED SECTION
Connector
Drum drive unit
Relay connector
11 - 20
Needle electrode
cleaner detection sensor
Fig. 11-35
Fig. 11-36
Connector
Drum drive unit
Fig. 11-37
May 2006 © TOSHIBA TEC