Toshiba e-STUDIO2500c Service Manual page 347

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO2500c:
Table of Contents

Advertisement

(3)
Raise the separation plate, and then take it
off upward.
Note:
When installing, check that the gap between
the pressure roller and separation plate is
within the range of 0.6 mm to 1 mm when the
fuser unit temperature is in the normal state.
If the gap is out of the specified value, be
sure to adjust it.
SERVICE HANDBOOK "3.16 Adjustment
of the separation plate gap (Fuser Unit)"
(4)
Release the harness on the rear side out of 3
clamps, and then disconnect 4 relay connec-
tors.
Note:
When installing them, pull the harness under
the stay.
(5)
Remove 1 screw, and then release the har-
ness out of 4 clamps.
May 2006 © TOSHIBA TEC
Separation plate
Fig. 15-26
Stay
Fig. 15-27
Harness
Fig. 15-28
e-STUDIO2500c/3500c/3510c FUSER UNIT / PAPER EXIT SECTION
15 - 23
Clamp
Relay connector
Clamp
15